165 lines
4.3 KiB
Text
165 lines
4.3 KiB
Text
|
@c Copyright 2002 Free Software Foundation, Inc.
|
||
|
@c This is part of the GAS manual.
|
||
|
@c For copying conditions, see the file as.texinfo.
|
||
|
@ifset GENERIC
|
||
|
@page
|
||
|
@node MSP430-Dependent
|
||
|
@chapter MSP 430 Dependent Features
|
||
|
@end ifset
|
||
|
@ifclear GENERIC
|
||
|
@node Machine Dependencies
|
||
|
@chapter MSP 430 Dependent Features
|
||
|
@end ifclear
|
||
|
|
||
|
@cindex MSP 430 support
|
||
|
@cindex 430 support
|
||
|
@menu
|
||
|
* MSP430 Options:: Options
|
||
|
* MSP430 Syntax:: Syntax
|
||
|
* MSP430 Floating Point:: Floating Point
|
||
|
* MSP430 Directives:: MSP 430 Machine Directives
|
||
|
* MSP430 Opcodes:: Opcodes
|
||
|
@end menu
|
||
|
|
||
|
@node MSP430 Options
|
||
|
@section Options
|
||
|
@cindex MSP 430 options (none)
|
||
|
@cindex options for MSP430 (none)
|
||
|
@code{@value{AS}} has only -m flag which selects the mpu arch. Currently has
|
||
|
no effect.
|
||
|
|
||
|
@node MSP430 Syntax
|
||
|
@section Syntax
|
||
|
@menu
|
||
|
* MSP430-Macros:: Macros
|
||
|
* MSP430-Chars:: Special Characters
|
||
|
* MSP430-Regs:: Register Names
|
||
|
* MSP430-Ext:: Assembler Extensions
|
||
|
@end menu
|
||
|
|
||
|
@node MSP430-Macros
|
||
|
@subsection Macros
|
||
|
|
||
|
@cindex Macros, MSP 430
|
||
|
@cindex MSP 430 macros
|
||
|
The macro syntax used on the MSP 430 is like that described in the MSP
|
||
|
430 Family Assembler Specification. Normal @code{@value{AS}}
|
||
|
macros should still work.
|
||
|
|
||
|
Additional built-in macros are:
|
||
|
|
||
|
@table @code
|
||
|
|
||
|
@item llo(exp)
|
||
|
Extracts least significant word from 32-bit expression 'exp'.
|
||
|
|
||
|
@item lhi(exp)
|
||
|
Extracts most significant word from 32-bit expression 'exp'.
|
||
|
|
||
|
@item hlo(exp)
|
||
|
Extracts 3rd word from 64-bit expression 'exp'.
|
||
|
|
||
|
@item hhi(exp)
|
||
|
Extracts 4rd word from 64-bit expression 'exp'.
|
||
|
|
||
|
@end table
|
||
|
|
||
|
They normally being used as an immediate source operand.
|
||
|
@smallexample
|
||
|
mov #llo(1), r10 ; == mov #1, r10
|
||
|
mov #lhi(1), r10 ; == mov #0, r10
|
||
|
@end smallexample
|
||
|
|
||
|
@node MSP430-Chars
|
||
|
@subsection Special Characters
|
||
|
|
||
|
@cindex line comment character, MSP 430
|
||
|
@cindex MSP 430 line comment character
|
||
|
@samp{;} is the line comment character.
|
||
|
|
||
|
@cindex identifiers, MSP 430
|
||
|
@cindex MSP 430 identifiers
|
||
|
The character @samp{$} in jump instructions indicates current location and
|
||
|
implemented only for TI syntax compatibility.
|
||
|
|
||
|
@node MSP430-Regs
|
||
|
@subsection Register Names
|
||
|
|
||
|
@cindex MSP 430 register names
|
||
|
@cindex register names, MSP 430
|
||
|
General-purpose registers are represented by predefined symbols of the
|
||
|
form @samp{r@var{N}} (for global registers), where @var{N} represents
|
||
|
a number between @code{0} and @code{15}. The leading
|
||
|
letters may be in either upper or lower case; for example, @samp{r13}
|
||
|
and @samp{R7} are both valid register names.
|
||
|
|
||
|
@cindex special purpose registers, MSP 430
|
||
|
Register names @samp{PC}, @samp{SP} and @samp{SR} cannot be used as register names
|
||
|
and will be treated as variables. Use @samp{r0}, @samp{r1}, and @samp{r2} instead.
|
||
|
|
||
|
|
||
|
@node MSP430-Ext
|
||
|
@subsection Assembler Extensions
|
||
|
@cindex MSP430 Assembler Extensions
|
||
|
|
||
|
@table @code
|
||
|
|
||
|
@item @@rN
|
||
|
As destination operand being treated as @samp{0(rn)}
|
||
|
|
||
|
@item 0(rN)
|
||
|
As source operand being treated as @samp{@@rn}
|
||
|
|
||
|
@item jCOND +N
|
||
|
Skips next N bytes followed by jump instruction and equivalent to
|
||
|
@samp{jCOND $+N+2}
|
||
|
|
||
|
@end table
|
||
|
|
||
|
|
||
|
@node MSP430 Floating Point
|
||
|
@section Floating Point
|
||
|
|
||
|
@cindex floating point, MSP 430 (@sc{ieee})
|
||
|
@cindex MSP 430 floating point (@sc{ieee})
|
||
|
The MSP 430 family uses @sc{ieee} 32-bit floating-point numbers.
|
||
|
|
||
|
@node MSP430 Directives
|
||
|
@section MSP 430 Machine Directives
|
||
|
|
||
|
@cindex machine directives, MSP 430
|
||
|
@cindex MSP 430 machine directives
|
||
|
@table @code
|
||
|
@cindex @code{file} directive, MSP 430
|
||
|
@item .file
|
||
|
This directive is ignored; it is accepted for compatibility with other
|
||
|
MSP 430 assemblers.
|
||
|
|
||
|
@quotation
|
||
|
@emph{Warning:} in other versions of the @sc{gnu} assembler, @code{.file} is
|
||
|
used for the directive called @code{.app-file} in the MSP 430 support.
|
||
|
@end quotation
|
||
|
|
||
|
@cindex @code{line} directive, MSP 430
|
||
|
@item .line
|
||
|
This directive is ignored; it is accepted for compatibility with other
|
||
|
MSP 430 assemblers.
|
||
|
|
||
|
@cindex @code{sect} directive, MSP 430
|
||
|
@item .arch
|
||
|
Currently this directive is ignored; it is accepted for compatibility with other
|
||
|
MSP 430 assemblers.
|
||
|
|
||
|
@end table
|
||
|
|
||
|
@node MSP430 Opcodes
|
||
|
@section Opcodes
|
||
|
|
||
|
@cindex MSP 430 opcodes
|
||
|
@cindex opcodes for MSP 430
|
||
|
@code{@value{AS}} implements all the standard MSP 430 opcodes. No
|
||
|
additional pseudo-instructions are needed on this family.
|
||
|
|
||
|
For information on the 430 machine instruction set, see @cite{MSP430
|
||
|
User's Manual, document slau049b}, Texas Instrument, Inc.
|