From a705637dcf7ffe063c9c0f3f190f57e44aaa63f2 Mon Sep 17 00:00:00 2001 From: rinpatch Date: Thu, 2 Jul 2020 01:53:27 +0300 Subject: [PATCH] Connection Pool: fix LRFU implementation to not actually be LRU The numbers of the native time unit were so small the CRF was always 1, making it an LRU. This commit switches the time to miliseconds and changes the time delta multiplier to the one yielding mostly highest hit rates according to the paper --- lib/pleroma/gun/connection_pool/worker.ex | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/lib/pleroma/gun/connection_pool/worker.ex b/lib/pleroma/gun/connection_pool/worker.ex index 418cb18c1..ec0502621 100644 --- a/lib/pleroma/gun/connection_pool/worker.ex +++ b/lib/pleroma/gun/connection_pool/worker.ex @@ -12,7 +12,7 @@ defmodule Pleroma.Gun.ConnectionPool.Worker do def init([key, uri, opts, client_pid]) do with {:ok, conn_pid} <- Gun.Conn.open(uri, opts), Process.link(conn_pid) do - time = :erlang.monotonic_time() + time = :erlang.monotonic_time(:millisecond) {_, _} = Registry.update_value(@registry, key, fn _ -> @@ -31,7 +31,7 @@ defmodule Pleroma.Gun.ConnectionPool.Worker do @impl true def handle_cast({:add_client, client_pid, send_pid_back}, %{key: key} = state) do - time = :erlang.monotonic_time() + time = :erlang.monotonic_time(:millisecond) {{conn_pid, _, _, _}, _} = Registry.update_value(@registry, key, fn {conn_pid, used_by, crf, last_reference} -> @@ -116,6 +116,6 @@ defmodule Pleroma.Gun.ConnectionPool.Worker do # LRFU policy: https://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.55.1478 defp crf(time_delta, prev_crf) do - 1 + :math.pow(0.5, time_delta / 100) * prev_crf + 1 + :math.pow(0.5, 0.0001 * time_delta) * prev_crf end end